They are used in Fire, Burglar & Emergency Alarm System.
Conventional Sounder Cum Strobe RE-25SS
Easy to install.
Operates on 24VDC
100db at 30cm.
Low Current.
Ceiling / Flush Wall Mount.
Conventional Sounder (UL Listed) RE-716SO
UL 464,UL – S525
2 Audible Tones Settings : Continuous and Temporal 3
Wall or Ceiling mountable
24VDC Operation
They are used in Fire, Burglar & Emergency Alarm System
Conventional Sounder Cum Strobe (UL Listed) RE-716SS
UL 1971, ULC -S525, UL 464, ULC-S526.
Low Current Draw
Flexible optic design to meet the light dispersion.
4 candella settings : 15/30/75/110 cd output.
2 audible tone settings : Continuous / Temporal 3.
Slim and sleek.
They are used in Fire, Burglar & Emergency Alarm System.
Conventional Manual Call Point RE-716 MR
Alarm status is indicated By Red color LED.
Operates on 24 VDC.
Green Colored for Emergency Release.
Yellow Colored for Abort.
1 No’s of CO & NC Output (Optional)
Conventional Manual Pull Station (UL Listed) RE-716P-IT
Lift and pull
Break glass cover
Weather and Explosion proof versions(optional).
All stations offer hex screw or key lock access
UL LISTED CONVENTIONAL FIRE ALARM PANEL
4 Zone Conventional Fire Alarm Panel (UL Listed) RE-2554
The microprocessor based UL listed 4 Zone conventional fire alarm control panel, the system has 16 X 2 LCD character, 4 zones detection circuit, 3 common potential free contacts &2 common NAC sounder output, inbuilt Rs-485 for repeater connectivity,wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection.
RE-2554 fire alarm control panel is designed with unique protocol to be used for small & medium establishments, Schools, hospitals, hotels, banks, commercial building, and small scale industries. Thus the system is user friendly with includes all standard to ensure ease for use and high reliability.
8 Zone Conventional Fire Alarm Panel (UL Listed) RE-2558
The microprocessor based UL listed 8 Zone conventional fire alarm control panel, the system has 16 X 2 LCD character, 8 zones detection circuit, 3 common potential free contacts & 2 common NAC sounder output, inbuilt RS-485 for repeater connectivity, wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection.
RE-2558 fire alarm control panel is designed with unique protocol to be used for small & medium establishments, Schools, hospitals, hotels, banks, residential / commercial building, and small scale industries. Thus the system is user friendly with includes all standard to ensure ease for use and high reliability.
900 SERIES CONVENTIONAL FIRE ALARM PANEL
Conventional Fire Alarm Panel (12 Zones to 128 Zones)
The microprocessor based CE mark 12 Zone Conventional fire alarm control panel, the system has 20 X 4 LCD Character with alpha numeric touch key pad, 12 zones detection circuit, 3 common programmable potential free contact & 2 common NAC Sounder output, inbuilt RS-485 for Networking TCP/IP, peer to peer & repeater connectivity, central monitoring mode poser supply, SMPS & Battery polarity & deep discharge protection.
RE-900 Series fire alarm control panel is designed with unique protocol to be used for small ,medium & Large establishments, Schools ,Hospitals, Hotels ,Banks ,Residential/Commercial building, and small scale industries. Thus this fire alarm system is user friendly and includes all standard to ensure case for use and high reliability.
Zones available- 12,16,20,24,32,48,64,96 and 128 Zones.
Conventional Repeater Panel (for 900 Series Fire Panel) RE-9032RP ,RE-9128RP ,RE-9256RP
20 X 4 Dot Matrix LCD display.
Alphanumeric keypads.
RS-485 Communication for Network Repeater.
System ON, AC ON, Battery ON, Charger ON indications.
Drill test / Evacuate facility.
Lamp test facility.
Maximum 16 Main panels includes repeaters that can connect in a Single Network through RS-485
CLEAN AGENT PANEL AND ACCESSORIES
AGENT RELEASE PANEL RE-120 GR
20 X 4 Dot Matrix LCD display.
Alphanumeric keypads.
RS-485 Communication for Network Repeater.
System ON, AC ON, Battery ON, Charger ON indications.
Drill test / Evacuate facility.
Lamp test facility.
Maximum 16 Main panels includes repeaters can be connected in a Single Network through RS-485
AGENT RELEASE PANEL (UL Listed) RE-25 AR
The Microprocessor based UL Listed Agent release panel has dual function of detection and release of gaseous agent. Also, the system has 16X2 LCD character, 4 zones detection circuit and 2main agent release circuits, it has various logic programmable options, the system has RTC facility, Auto & manual operational facility, solenoid output with ON and OFF timer with solenoid coil monitoring facility, programmable Main output facility, gas inhabit and instant release, manual release with time delay or without time delay and pressure low sensing facilities.Switch mode power supply- SMPS & Battery polarity & Deep discharge protection.
RE- 25AR will have all safety features to prevent accidental release, user friendly programmable options, the system is ideal choice to protect areas like, Server rooms, data centre , paint booths and hazards areas etc. Thus the system is user friendly that includes all standard to ensure ease for use and high reliability.
MANUAL PULL STATION (ABORT) (UL Listed) RE-716 PIT (Y)
Lift and pull.
Break glass cover.
Weather and explosion proof version.
All station offer hex screw or key low access.
MANUAL PULL STATION (RELEASE) (UL Listed) RE-716 PIT (G)
Lift and pull.
Break glass cover.
Weather and explosion proof version.
All station offer hex screw or key low access.
MANUAL CALL POINT (ABORT) RE-716 MY
Alarm status is indicated By Red color LED.
Operates on 24 VDC.
Green Colored for Emergency Release.
Yellow Colored for Abort.
1 No’s of CO & NC Output (Optional).
MANUAL CALL POINT (RELEASE) RE-716 MG
Alarm status is indicated By Red color LED.
Operates on 24 VDC.
Green Colored for Emergency Release.
Yellow Colored for Abort.
1 No’s of CO & NC Output (Optional).
RAVEL SPECIAL DETECTORS
DUCT DETECTOR RE-428 DU-C
High efficient single sampling tube
Easy to install
One-pipe air sampling system
Patented venturi pipe and duct housing
Test hole on cover
Simple service and maintenance
GAS LEAK DETECTOR RE-386-LP , RE-386-NG ,RE-386-CO
Advanced algorithms provide advanced detection, discrimination.
Stable gas sensing chamber. No adjustment or replacement required
High immunity against unwanted alarms
Surface-mount device (SMD) circuit board design
4-wire system operation
Detector auto-reset once gas levels fall below alarm threshold levels
Internal reed switch for hush and test functions
DC 24 V operation
N/O alarm relay output
70 dB internal sounder
Easy installation and no programming required
Connects to zone monitor for use with addressable control and indicating equipment
Sleek low-profile housing design
Low maintenance
BEAM DETECTOR (UL Listed) EAZY BEAM DS
Product Overview This device can be installed easily and quickly by a single person in single point of wiring & commissioning. Further, it has special feature to compensate automatically for natural building movement to continuously maintaining alignment by building movement tracking technology.
Salient Features
Auto alignment
Easy Installation
Standalone Detector
Salient Features
Alignment mode switch, alignment directional buttons and configuration switches for alarm response threshold
2 Green LEDs and 1 Yellow LED for alignment status.
System status : Green LED flashing every 10 sec in normal condition
Red LED flashing every 10 sec in alarm condition
Yellow LED flashing every 10 sec for obscuration or every 5 sec for contamination in Fault condition .
Flat front face with enclosed optics.
Cleaning the optics does not affect alignment.
UL Listed.
BEAM DETECTOR RE-428HR (100 Meter)
The RE-428 Series beam smoke detector is designed for smoke detection at the start of a fire. And it is especially suitable for protection of indoor spaces, in which the appearance of smoke is likely during ignition of a fire, and where, due to a large space area, installation of a greater number of point smoke detectors would be necessary. The RE-428 Series beam smoke detector and the prism reflector or reflector panel are installed on opposite walls of a room
BEAM DETECTOR RE-428FR (50 Meter)
The RE-428 Series beam smoke detector is designed for smoke detection at the start of a fire.Hence it is especially suitable for protection of indoor spaces, in which the appearance of smoke is likely during ignition of a fire, and where, due to a large space area, installation of a greater number of point smoke detectors would be necessary. Moreover, RE-428 Series beam smoke detector and the prism reflector or reflector panel are installed on opposite walls of a room
SINGLE LOOP ADDRESSABLE FIRE ALARM SYSTEM
ONE LOOP ADDRESSABLE FIRE ALARM PANEL MONITI
CE approved – Single Loop Analogue addressable fire alarm panel with 127 devices of any combination with 20 loop powered sounders in addition .supports single repeater panel, Touch key panel with USB inbuilt for Laptop connectivity. Front Panel programmable.
MONITI REPEATER PANEL MONITI-RP
Complies EN54
160 (40X4) character LCD Display
RS 485 communication for repeater
One Programmable form C relay for fire
Extensive built in transient protection
Common fire, fault LED indication
ADDRESSABLE SMOKE DETECTOR RE-337 S
Complies with EN 54.
Dual LED’s for 360° visibility.
Advanced detection and communication protocol.
Stable photoelectric smoke sensing chamber.
No adjustment or replacement required
Polarity insensitive.
Easy installation and maintenance.
Sleek low-profile housing design.
Regular 100mm base.
Simple Soft address programming for Easy installation.
ADDRESSABLE HEAT DETECTOR RE-337 H
Complies with En54.
Dual LED’s for 360 visibility.
Durable sensor.
No adjustment or replacement required.
Advanced detection and communication protocol.
Polarity insensitive.
Easy installation and maintenance.
Sleek low-profile housing design.
Regular 100mm base.
Simple Soft address programming for Easy installation.
ADDRESSABLE MULTI SENSOR DETECTOR RE-337 SH
Complies with EN 54.
Dual LED’s for 360° visibility.
Advanced detection and communication protocol.
Stable photoelectric smoke sensing chamber.
No adjustment or replacement required.
Polarity Insensitive.
Easy installation and maintenance.
Sleek low-profile housing design.
Regular 100mm base.
Simple Soft address programming for Easy installation.
ADDRESSABLE ZONE MODULE RE-737MZ
Inbuilt Isolator.
Module Status by RED LED.
Analogue Communication with the panel.
Module Addressing by Software / 8 way DIP Switches.
Low Standby Current.
ADDRESSABLE INPUT OUTPUT MODULE RE-737MX
Inbuilt Isolator.
Module Status by RED LED.
Analogue Communication with the panel.
Module Addressing by Software / 8 way DIP switches .
Low Standby Current.
Available with suitable back boxes
ADDRESSABLE RELAY MODULE RE-737MR
Inbuilt Isolator.
Module Status by RED LED.
Analogue Communication with the panel.
Module Addressing by Software / 8 way DIP switches .
Low Standby Current.
Available with suitable back boxes.
ADDRESSABLE MONITOR MODULE RE-737MM
Inbuilt Isolator.
Module Status by RED LED.
Analogue Communication with the panel.
Module Addressing by Software / 8 way DIP switches .
Low Standby Current.
Available with suitable back boxes.
ADDRESSABLE CONTROL MODULE RE-737MC
Inbuilt Isolator.
Module Status by RED LED.
Analogue Communication with the panel.
Module Addressing by Software / 8 way DIP switches .
Low Standby Current.
Available with suitable back boxes.
ADDRESSABLE MANUAL CALL POINT RE-737M
Complies EN54-11
Type “A” Indoor Use
Re-settable by an element kit
Suitable for flush or surface mounting
Inbuilt – Isolator
Soft Addressing using programming tool
Low Standby Current
ADDRESSABLE LOOP SOUNDER RE-24LS
Complies EN54-11
Type “A” Indoor Use
Suitable for flush or surface mounting
Inbuilt – Isolator
Soft Addressing using programming tool
Low Standby Current
MULTI LOOP FIRE ALARM PANEL AND ACCESSORIES
4 LOOP ANALOGUE ADDRESSABLE FIRE ALARM PANEL (UL Listed) AVANI
UL listed – Single Loop Expandable Up To 4 Loop Analogue addressable fire alarm panel with 254 devices of any combination in a loop,1016 devices of any combination in a panel, Networkable upto 8 panels in a node. Touch key panel with USB inbuilt for Laptop connectivity. Front panel programmable with Loop redundancy.
LOOP CARD (UL Listed) RE-LC
RE-LC Loop Card for AVANI is an intelligent addressable fire alarm control panel. And up to 254 devices can be connected to a single loop card. Also, this loop card can plugged in to slot provided in the motherboard of Main panel (Avani). Thus RE-LC Loop Card is compatible with Addressable Detectors, Manual Call Points, Modules etc., The status of the loop shown by dual colour LED.
PASSIVE REPEATER PANEL AVANI-RP
The Avani-RP repeater panel is a compact remote unit for Ravel-Avani Intelligent Analogue Addressable fire Alarm panel. It repeats all the indications of FACP in standalone or in network Panel. Also, it has (40X4) 160 character LCD Display.
This repeater is connected to Avani FACP using RS 485 communication network. Any communication fault or any loss in communication due to cable fault is indicated in this repeater panel. Also, the display parameters on this fire alarm system can be selected individually to suit the requirement of each remote area
ADDRESSABLE SMOKE DETECTOR (UL Listed) RE-317D-SL
UL Listed Analogue addressable Smoke Sensor detectors with smoke detectors with 8 digit dip switches for ( 1 to 254) address settings. Dual LED indication for 360-degree visibility, milky white in color, shall be polarity insensitive, easy to install, advanced detection and communication protocol with insect filter chamber
ADDRESSABLE HEAT DETECTOR (UL Listed) RE-317D-HL
UL Listed Analogue addressable Smoke Sensor detectors with smoke detectors with 8 digit dip switches for ( 1 to 254) address settings. Dual LED indication for 360-degree visibility, milky white in color, shall be polarity insensitive, easy to install, advanced detection and communication protocol with insect filter chamber
ADDRESSABLE MULTI SENSOR DETECTOR (UL Listed) RE-317D-SHL
UL Listed Analogue addressable Multi Sensor detectors with smoke detectors and the combination of heat detectors with the fixed temperature of 59 degrees Centigrade and Rate of raise facility of 11.1.Deg C /min with 8 digit dip switches for ( 1 to 254) address settings. Dual LED indication for 360-degree visibility, milky white in color, shall be polarity insensitive, easy to install, advanced detection and communication protocol with insect filter chamber
ADDRESSABLE ZONE MODULE (UL Listed) RE-717MZ
Zone interface module used to connect the conventional smoke, heat and multi sensor detector to addressable fire alarm control panels also the module is used to integrate with Beam detectors to addressable fire alarm system. Shall have RED colored LED for status indications with 8 digit DIP switch for address settings
Zone interface module used to connect the conventional smoke, heat and multi sensor detector to addressable fire alarm control panels also the module is used to integrate with Beam detectors to addressable fire alarm system. Shall have RED colored LED for status indications with 8 digit DIP switch for address settings
ADDRESSABLE RELAY MODULE (UL Listed) RE-717MR
UL listed control relay module with dual potential free contact to integrate with any third party systems having RED coloured LED for status indications with 8 digit Dip switch for address settings
ADDRESSABLE MONITOR MODULE (UL Listed) RE-717MM
UL listed control monitor module with dual potential free contact to integrate with any third party systems having RED coloured LED for status indications with 8 digit Dip switch for address settings
ADDRESSABLE ISOLATOR MODULE (UL Listed) RE-717MI
The isolator module to be installed between every 16 devices to isolate the circuit from single short circuit on the analogue addressable loop cable, this is non addressable device with yellow LED for status indications.
ADDRESSABLE CONTROL MODULE (UL Listed) RE-717MC
UL Listed Control Module to integrate with Conventional Audible devices like Sounder, Sounder cum strobe, strobe, bell etc., Also having supervisory features for NAC circuit as well as the power supply input. Capable to connect multiple notification devices in single module having RED colored LED for status indications with 8 digit Dip switch for address settings.
GRAPHIC SOFTWARE AVANI-SOFT
CONTROL MONITORING SOFTWARE AVANI-CMS
PUBLIC ADDRESS SYSTEM
PUBLIC ADDRESS MAIN CONSOLE EKONICS
4 audio inputs can configure to any combination of 8 or multiple of 8 outputs.
19” Rack mountable.
All-call or zone wise paging.
Built-in 12 Programmable DVA/Alarm messages.
40×4 LCD Display.
USB 2.0 Interface for PC connectivity.
PC based Router configuration.
Interface with Avani via RS-485
3 Levels of Password protection.
RS485 communication facility.
Event log with RTC.
User selectable Volume level & 3 Band Equalizer for audio inputs.
Zone wise input priority level, permanent input, scheduled digital voice announcer.
All field circuits are supervised.
Inbuilt 250W Amplifier (2X125W)
Zone wise selection through keypad
Programmable one form C Relay
Zone Selection, Fault status in unambiguous colored LED
PUBLIC ADDRESS MAIN CONSOLE e'Scape
19”, Rack mountable.
System ON, Power Fault, Common fault indications.
Membrane Keypad for user friendly operation.
Inbuilt 250 watts amplifier.
Additional Amplifier can expand up to 250W.
One Inbuilt Microphone for announcement.
Zone Wise (Speaker line) Selection facility with LED indication.