Automatic CO2 flooding systems are intended to control flames fast by flooding enclosed places with carbon dioxide (CO2) gas. CO2 is a colorless, odorless, non-conductive gas that displaces oxygen, lowering the oxygen content in the area and limiting combustion. CO2 flooding systems are often utilized in important places such as server rooms, control rooms, archives, museums, and other facilities where water-based fire suppression systems would be ineffective owing to the danger of water damage to sensitive equipment or precious assets.

Here’s a general overview of how automatic CO2 flooding systems work:

Detection and activation: Fire detectors, such as heat or smoke detectors, are normally strategically located in the protected zone. When a fire is detected, the detectors communicate with the control panel, which initiates the CO2 flooding system.

Valve Operation:

The control panel initiates CO2 release by providing an electrical signal to the solenoid valves that regulate CO2 gas flow. These valves are typically positioned in the main CO2 supply line and open to allow CO2 to enter the protected compartment.

Discharge and Distribution:

When the solenoid valves open, high-pressure CO2 gas is expelled into the protected space from the storage cylinders or tanks. The CO2 gas is delivered via a network of distribution pipes or nozzles that are meticulously built and positioned to provide effective coverage of the protected area.

Oxygen Displacement:

Because CO2 gas is heavier than air, it sinks and displaces oxygen from the bottom up. The CO2 gas, when it fills the covered zone, drops the oxygen concentration below the amount necessary for combustion, thereby extinguishing the fire.

Time Delay and Monitoring:

Some CO2 flooding systems may have a time delay option that permits people to leave the safe zone before the CO2 is discharged. The system may additionally contain pressure sensors or other monitoring equipment to guarantee that the proper concentration of CO2 is kept in the area for a long enough period of time to effectively suppress the fire.

System Reset and Recharge:

After the fire has been extinguished, the CO2 flooding system must be restarted and refilled. Closing the solenoid valves, venting the protected chamber to remove the CO2 gas, and recharging the system with fresh CO2 gas for the next usage are usual procedures.

Call us or submit the contact us form on the PixelDistributor website for your inquiries about our products and pricing

It should be noted that CO2 flooding devices should only be used by skilled persons who follow the manufacturer’s instructions and local fire protection standards. Proper system maintenance, inspection, and testing are also required to assure the system’s dependability and efficacy in fire suppression. It is advised that you consult with a qualified fire prevention specialist when designing, installing, and maintaining automatic CO2 flooding systems in compliance with local rules and standards.